local automatism

RS4

application

Simple solution with the management of pumpings, L cleansing and overpressure, the RS4 :
  • Control starting and L stop from 1 to 4 groups (16 thresholds).
  • Provides L power supply of the sensor.
  • Carry out L posting direct of measurement, and value while running.
  • Manage the permutations.
  • Takes into account the defects groups and measurements.
  • S adapts to tariffings full hours/off-peak hours.
  • Allows an operation moving and stops forced.
  • Integrate L use of emergency power units.

simple and reliable use

  • Its parameter setting by a levelling keyboard of 11 keys, and the direct reading of information on its screen LCD confers an extreme simplicity to him.
  • Its management of emergency power units, its monitoring of startings of machines, its capacity to start forced steps or stops, like its system of temporization, ensure a total reliability to him.

robust

  • This material profits from guarantee 2 years, including risk of the lightning(1).

documentation

(1) the protection of the power supply 220 with PRO TAS220 and the loop with PRO TAS30 are imperative.

relay of thresholds

relay of threshold

application

Usable with any type of sensor delivering a current of measurement 4-20 my, these relays of thresholds allow either the automation of orders in relation to measurement, or the indication of the points of instructions.
  • With or without adjustment of hysteresis, the relays of thresholds authorize the walk or the stop of materials to the fixed values.
  • For the relays of order, the exits with dry contacts 5A 230 V reduce the need for relayage considerably.

simple and reliable use

  • Relays of order or relays of alarm, materials are protected from the industrial parasites and the atmospheric disturbances.
  • Even provided with the functions permutation or degraded walk, the implementation and the use of relays remain extremely simple.

robust

  • Used according to our regulations, the relays of thresholds are guaranteed two years including risk of the lightning (1).
(1) the protection of the power supply 220 with PRO TAS220 and the loop with PRO TAS30 are imperative.

 

Réf. Case Nb sections
skeletal
Tempo.
permutation
Exits Specificities Alim. Impedance of entée
acceptable
RS1 35 mm
Rail_DIN
1 Section
(2 thresholds)
Not 1 make-break contact 5A 230V Indication of the order by indicator. 230V~ 115 Ohms
with 20mA
RS1T 35 mm
Rail_DIN
1 Section
(2 thresholds)
Tempo. 1 make-break contact 5A 230V Indication of the order and temporization
by indicators.
230V~ 115 Ohms
with 20mA
RA2 35 mm
Rail_DIN
2 thresholds
independent
Not 2 make-break contacts 5A 230V
Hysteresis fixes 5%
Indication of the order by indicators
Adjustment of the thresholds from 0 to 100%,
230V~ 115 Ohms
with 20mA
RS2
RS2A
70 mm
Rail_DIN
2 Sections
(4 thresholds)
Not 2 make-break contacts 5A 230V
1 defect signal 300mA 230V
Indication of the order and the defect
by indicators.
230V~ 105 Ohms
with 20mA
RS2T
RS2TA
70 mm
Rail_DIN
2 Sections
(4 thresholds)
Tempo.
Permutation
2 make-break contacts 5A 230V
1 defect signal 300mA 230V
Indication of the order, the defect and temporization by indicators.
Go or stop on defect signal.
230V~ 105 Ohms
with 20mA
RDA2 105 mm
Rail_DIN
2 thresholds
independent
Not 1 exit 4/20mA proportional to the difference of the 2 entries
2 make-break contacts 5A 230V
1 defect signal 5A 230V
Entées Insulation/Left/power supply 400V 50Hz.
Indication of the order and the defect
by indicators.
230V~ Tension
delivered
19 with 35V
OPUS 105 mm
Rail_DIN
Transducer
3 Sections
(6 thresholds)
Tempo.
Permutation
3 make-break contacts 5A 230V likely to be stripped
1 defect signal 5A 230V likely to be stripped
Numerical Ultrasound unit, automatism
Screen LCD and Keyboard.
24V~ Digital link
RS4 210 mm
Rail_DIN
2x4 Sections
(16 thresholds)
Tempo.
Permutation
Help
4 make-break contacts 5A 230V
1 defect signal 5A 230V
Directly post measurement and the current.
Takes into account the defects groups and measurements.
Adapt to tariffings full hours/off-peak hours.
Allows an operation moving and stops forced.
Integrate the use of emergency power units.
230V~ Tension
delivered
20V